Simultaneous process density (specific gravity), Single instrument for viscosity and temperature measurement |
Small form factor for simple installation | In Newtonian and non-Newtonian fluids Stable, repeatable measurements in real time |
Kinematic and dynamic viscosity measurements | All metal (316L stainless steel) construction | Not affected at all by installation conditions |
7500psi (500bar) and Operates at 575°F (300°C) |
Threads, flanges and sanitary process fittings | Easy cleaning, maintenance or no reconfiguration required |
Extend to multiple locations/installations without application re-engineering |
Specification
Fluid measurement
Density range | 0.4-1.5 g / cc |
Density Accuracy | 0.01 g/cc (0.001g/cc and higher accuracy available) |
Viscosity range | 1 to 3,000 cP (standard) wider range possible |
Viscosity accuracy | Offers accuracy better than 1% of reading (typical) to 5% of reading |
Reproducibility | Better than 1% of reading |
Temperature | Pt1000 (DIN EN 60751 cIass B) |
Operating conditions
Process fluid temperature | -40 up to 300°C (575°F) |
Ambient temperature | -40 up to 150°C |
Pressure range | Up to 7,500 psi (500 bar) |
How it works
The Rheonics SRV fluid viscometer measures viscosity via a torsional resonator. A torsional resonator has one end immersed in the fluid under test.
The higher the viscosity of the fluid, the higher the mechanical damping of the resonator. By measuring the attenuation, the product of viscosity and density can be calculated using Rheonics’ proprietary algorithm. The resonator is excited and detected through an electromagnetic transducer mounted on the sensor body. Damping is measured with Rheonics’ patented sensing and evaluation electronics, which achieve stable, high accuracy and repeatable readings based on Rheonics’ proven gated phase-locked loop technology.