Features

Identifying increased wear Grease deterioration detection Works on all types of grease
Fully digital solution Web-based distributed monitoring Wind turbine
Roller bearing wear detection Grease deterioration monitoring Greece condition monitoring solution

Specification

Oil sensor specifications

Range inversion 0.1 to 100,000 pS/m
(Optional, high range: 0.1 to 2.000.000 pS/m)
Relative permittivity 1 to 5
Sensitivity Conductivity 0.1 pS/m
Relative permittivity 1*10^‑6

Temperature and pressure

Maximum Oil Pressure 20℃ ~ 60barg (68℉ ~ 870psig)
Oil temperature ‑10℃~+70℃
(Optional, high temperature: -10° to + 150°C)
(Optional, low temperature: ‑40° to + 65°C)
Operating Temperature ‑20℃~+70℃

Material

Sensor Material Stainless steel (ball and carrier)
and aluminum (head)
Cable 3 meters, shielded
(Optional, other cable lengths)

Between

Between ¼” Swagelok® for 6mm od tubing
(Optional connector available)
Communication interface Serial communication via RS232/RS232‑USB
(Options: LAN, GSM, Profibus, Modbus,
CAN, 0..10V, 0/4..20mA)

Electrical Requirements

Electricity 115/230VAC, 50/60Hz
(Optional, +24VDC)

Weight and dimensions

Dimensions Sensor: 103 (height) x 70 (diameter)
Communication unit: 210 x 250 x 165
Communication module: 87 x 110 x 30
Net weight (sensor) 1.7kg communication device: 4.45kg
Communication module: 0.25kg